Thermal–Hydraulic and Net-Energy Assessment of Transverse Baffles in a Narrow Rear Air Channel for Cooling the Photovoltaic Arrays of Solar Irrigation Pumping Systems in Hot Climates
DOI:
https://doi.org/10.46649/fjias.v2.si1.18Keywords:
solar irrigation pumping, photovoltaic cooling, baffled channel, laminar forced convection, net power gain, hot climateAbstract
Solar photovoltaic (PV) water pumping is spreading rapidly in Iraqi agriculture, but the electrical output of PV arrays, and hence the volume of irrigation water pumped, falls as module temperature rises during the hot summer months when crop water demand peaks. Forced air flow through a narrow channel behind the module is a low-cost, water-free way to limit cell temperature, and transverse baffles are often proposed to intensify it. Baffles are normally judged with the equal-pumping-power criterion PEC = (Nu/Nu0)/(f/f0)1/3, which was derived for heat exchangers and does not account for the electrical value of a lower PV temperature. This study simulates laminar forced convection (Re = 100–600, Pr = 0.71) in a parallel-plate channel whose upper wall receives a uniform heat flux from the PV rear surface, with adiabatic baffles mounted on the opposite, insulated wall. The baffle blockage ratio (e/H = 0.3–0.7) and number (n = 3, 5, 7 over a heated length of 10H) were varied in 40 cases. The stream function–vorticity equations were solved with a conservative TVD finite-volume scheme. The solver reproduces the exact fully developed Nusselt number (5.385) and the analytical energy balance within 1.4%. Baffles raised Nu by 12–148% and lowered the maximum heated-wall temperature by 5–49%, but the friction factor rose by a factor of 1.6–38, so that PEC remained between 0.67 and 0.96 in every case. In contrast, a net-energy analysis for a 5 mm channel under Baghdad summer conditions shows that the electrical gain from the lower module temperature exceeds the additional fan power in all 36 baffled cases. The largest net gain (9.8 W m−2, 5.4% of the reference output) was obtained with the highest blockage at Re = 100, whereas at Re = 600 a moderate blockage (e/H = 0.5) was best (2.9 W m−2). Correlations for Nu and f are proposed (mean deviations 2.7% and 3.7%). The conventional PEC can therefore reject baffle designs that are energetically beneficial for cooling the PV arrays of solar irrigation pumps, and the optimum blockage decreases as the flow rate increases.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Jaber Ali Zghair (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.
This work is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).
https://creativecommons.org/licenses/by/4.0/



